netapp 2个控制器spare盘分配

存储:netapp2050

控制器1:fas2050a  控制器2:fas2050b

问题:2012-1-17 netapp硬盘告警红灯,进入web管理界面发现fs2050b已无spare盘。

解决方法:

1)、查询fas2050b上disk是否有故障盘:

fas2050b*> disk show -v
  DISK       OWNER                  POOL   SERIAL NUMBER   
------------ -------------          -----  -------------   
1a.19        fas2050a  (135051920)   Pool0  3LM5L1EV000099062LEM
1a.44                  (80009292)   Pool0  3LM5L3VP000099062PL7
1a.42        fas2050a  (135051920)   Pool0  3LM5L4340000990600XR
1a.29        fas2050a  (135051920)   Pool0  3LM5L406000099062PH5
1a.36        fas2050a  (135051920)   Pool0  3LM5L3ZZ00009906PG5R
1a.16        fas2050a  (135051920)   Pool0  3LM5L1FX000099062NUT
1a.40        fas2050a  (135051920)   Pool0  3LM5L3YB00009906PJVD
1a.58        fas2050b  (135051995)   Pool0  3LM61GRZ000099239GD4
1a.33        fas2050a  (135051920)   Pool0  3LM5L3Y600009906PJUT
1a.61        fas2050b  (135051995)   Pool0  3LM61FNQ00009923YGS1
1a.45        fas2050a  (135051920)   Pool0  3LM5L42F00009906H42Y
1a.38        fas2050a  (135051920)   Pool0  3LM5L3Z30000990602US
1a.37        fas2050a  (135051920)   Pool0  3LM5L3XS00009906PJVM
1a.23        fas2050a  (135051920)   Pool0  3LM5L15B000099062KSJ
1a.20        fas2050a  (135051920)   Pool0  3LM5L1GB00009906PJ5F
1a.60        fas2050b  (135051995)   Pool0  3LM61FK600009924JFZ6
1a.35        fas2050a  (135051920)   Pool0  3LM5JNEL0000990601VP
1a.28        fas2050a  (135051920)   Pool0  3LM5L1860000990621WJ
1a.50        fas2050b  (135051995)   Pool0  3LM61FMY00009923H2S9
1a.53        fas2050b  (135051995)   Pool0  3LM61GPY000099239GBF
1a.56        fas2050b  (135051995)   Pool0  3LM61FHN00009923H2V3
1a.41        fas2050a  (135051920)   Pool0  3LM5L3Y500009906PJVQ
1a.17        fas2050a  (135051920)   Pool0  3LM5L1G800009906PJ5N
1a.59        fas2050b  (135051995)   Pool0  3LM48BWF00009923H33U
1a.43        fas2050a  (135051920)   FAILED 3LM5L42B0000990601VK
1a.27        fas2050a  (135051920)   Pool0  3LM5L19W000099062N1K
1a.49        fas2050b  (135051995)   Pool0  3LM61GSZ000099239GBU
1a.18        fas2050a  (135051920)   Pool0  3LM5L1EX000099062LDW
1a.55        fas2050b  (135051995)   Pool0  3LM61FGB00009923H2P5
1a.32        fas2050a  (135051920)   Pool0  3LM61X1A00009913Q8FW
1a.54        fas2050b  (135051995)   Pool0  3LM61FH400009923H3M2
1a.21        fas2050a  (135051920)   Pool0  3LM5L1TD000099062LU4
1a.57        fas2050b  (135051995)   Pool0  3LM61FM400009924K4XP
1a.34        fas2050a  (135051920)   Pool0  3LM5L4QQ000099061ZPY
1a.26        fas2050a  (135051920)   Pool0  3LM5L1L8000099062MX4
1a.51        fas2050b  (135051995)   Pool0  3LM61FMX00009923H3T8
1a.24        fas2050a  (135051920)   Pool0  3LM5L1M200009906PJZD
1a.39        fas2050a  (135051920)   Pool0  3LM5L3XX0000990616SL
1a.22        fas2050a  (135051920)   Pool0  3LM5L3LP000099062N5W
1a.25        fas2050a  (135051920)   Pool0  3LM5L182000099062N68
1a.52        fas2050b  (135051995)   Pool0  3LM3AMLZ00009828WB5B
 发现1a.44,盘已损坏。

2)查询spare盘:

fas2050b*> sysconfig -r
Aggregate aggr0 (online, raid_dp) (block checksums)
  Plex /aggr0/plex0 (online, normal, active)
    RAID group /aggr0/plex0/rg0 (normal)

RAID Disk Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      --------- ------  ------------- ---- ---- ---- ----- --------------    --------------
      dparity   1a.55   1a    3   7   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      parity    1a.56   1a    3   8   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.60   1a    3   12  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.52   1a    3   4   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.49   1a    3   1   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.50   1a    3   2   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.51   1a    3   3   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.61   1a    3   13  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.53   1a    3   5   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.54   1a    3   6   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.57   1a    3   9   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.58   1a    3   10  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.59   1a    3   11  FC:A   -  FCAL 15000 272000/557056000  280104/573653840

Spare disks (empty)

Partner disks

RAID Disk       Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------       ------  ------------- ---- ---- ---- ----- --------------    --------------
partner         1a.21   1a    1   5   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.27   1a    1   11  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.38   1a    2   6   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.17   1a    1   1   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.33   1a    2   1   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.36   1a    2   4   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.24   1a    1   8   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.34   1a    2   2   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.32   1a    2   0   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.25   1a    1   9   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.16   1a    1   0   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.28   1a    1   12  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.18   1a    1   2   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.42   1a    2   10  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.40   1a    2   8   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.37   1a    2   5   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.45   1a    2   13  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.26   1a    1   10  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.22   1a    1   6   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.39   1a    2   7   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.29   1a    1   13  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.19   1a    1   3   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.20   1a    1   4   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.23   1a    1   7   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.35   1a    2   3   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.41   1a    2   9   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.43   1a    2   11  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
spare 为空,说明spare已顶上去了。这时候这个控制器已经没有spare盘,故web管理界面出现无spare的警告。

3)查看fas2050a上得spare盘情况:

fas2050a*> sysconfig -r
Aggregate aggr0 (online, raid_dp) (block checksums)
  Plex /aggr0/plex0 (online, normal, active)
    RAID group /aggr0/plex0/rg0 (normal)

RAID Disk Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      --------- ------  ------------- ---- ---- ---- ----- --------------    --------------
      dparity   1a.17   1a    1   1   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      parity    1a.19   1a    1   3   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.21   1a    1   5   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.16   1a    1   0   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.18   1a    1   2   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.20   1a    1   4   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.22   1a    1   6   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.23   1a    1   7   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.24   1a    1   8   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.25   1a    1   9   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.26   1a    1   10  FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.27   1a    1   11  FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.28   1a    1   12  FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.32   1a    2   0   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.33   1a    2   1   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.34   1a    2   2   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.35   1a    2   3   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.36   1a    2   4   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.37   1a    2   5   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.38   1a    2   6   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.39   1a    2   7   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.40   1a    2   8   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.45   1a    2   13  FC:B   -  FCAL 15000 272000/557056000  280104/573653840

Spare disks

RAID Disk       Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------       ------  ------------- ---- ---- ---- ----- --------------    --------------
Spare disks for block or zoned checksum traditional volumes or aggregates
spare           1a.29   1a    1   13  FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
spare           1a.41   1a    2   9   FC:B   -  FCAL 15000 272000/557056000  280104/573653840 
spare           1a.42   1a    2   10  FC:B   -  FCAL 15000 272000/557056000  280104/573653840

4)、将坏盘踢走:

fas2050b*> disk remove_ownership 1a.44 -f
disk remove_ownership: Disk 1a.44 is not owned by this node.
fas2050b*> 
fas2050b*> disk reassign 1a.44 -s 80009292 -d 135051995
disk reassign: Can only be run in maintenance mode or during takeover in advanced mode
fas2050b*> 
fas2050b*> 
fas2050b*>

5)、分配新的spare给控制器2
fas2050b*> disk assign  1a.43 -s 135051995
disk assign: Assign failed for one or more disks in the disk list.
fas2050b*> 
fas2050b*> disk assign  1a.43 -s 135051995
disk assign: Assign failed for one or more disks in the disk list.

6)、查看是否已分配

fas2050b*> sysconfig -r
Aggregate aggr0 (online, raid_dp) (block checksums)
  Plex /aggr0/plex0 (online, normal, active)
    RAID group /aggr0/plex0/rg0 (normal)

RAID Disk Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      --------- ------  ------------- ---- ---- ---- ----- --------------    --------------
      dparity   1a.55   1a    3   7   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      parity    1a.56   1a    3   8   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.60   1a    3   12  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.52   1a    3   4   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.49   1a    3   1   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.50   1a    3   2   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.51   1a    3   3   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.61   1a    3   13  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.53   1a    3   5   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.54   1a    3   6   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.57   1a    3   9   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.58   1a    3   10  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
      data      1a.59   1a    3   11  FC:A   -  FCAL 15000 272000/557056000  280104/573653840

Spare disks

RAID Disk       Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------       ------  ------------- ---- ---- ---- ----- --------------    --------------
Spare disks for block or zoned checksum traditional volumes or aggregates
spare           1a.42   1a    2   10  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
spare           1a.43   1a    2   11  FC:A   -  FCAL 15000 272000/557056000  280104/573653840

Partner disks

RAID Disk       Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------       ------  ------------- ---- ---- ---- ----- --------------    --------------
partner         1a.21   1a    1   5   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.27   1a    1   11  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.38   1a    2   6   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.17   1a    1   1   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.33   1a    2   1   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.36   1a    2   4   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.24   1a    1   8   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.34   1a    2   2   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.32   1a    2   0   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.25   1a    1   9   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.16   1a    1   0   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.28   1a    1   12  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.18   1a    1   2   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.40   1a    2   8   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.37   1a    2   5   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.45   1a    2   13  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.26   1a    1   10  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.22   1a    1   6   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.39   1a    2   7   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.29   1a    1   13  FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.19   1a    1   3   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.20   1a    1   4   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.23   1a    1   7   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.35   1a    2   3   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
partner         1a.41   1a    2   9   FC:A   -  FCAL 15000 272000/557056000  280104/573653840 
OK!!

时间: 2024-10-10 17:18:49

netapp 2个控制器spare盘分配的相关文章

3.21电脑重装“operation not found system ”和xp分盘”分配表有标记为已使用的未用簇”

问题一.是用光盘重装系统后重启,提示operation not found system ①考虑是系统问题,没装好,还是引导文件丢失;换新盘装,若还是一样; ②分析认为是分区问题,必须是活动分区+主分区,进pe用DG激活c盘为活动分区,重启就好了 总结遇此类问题可按②①顺序来尝试解决,后续其他可能性再补充 问题二.系统装好了,由于前修理者手误,c盘有400G,分盘操作 ①右键电脑→管理→磁盘管理→右键对应盘→压缩卷,(xp系统没有这功能) ②使用DG从c盘建立新分区,提示"文件分配表中有标记为已

netapp 培训

RAID0: 条带化RAID1:镜像RAID5: 条带化,容量是 N-1块盘RAID4: 条带化,一个固定盘做校验,性能瓶颈在检验盘,校验盘被频繁读写,成为热点盘.扩容时,比较容易.RAID-DP: double parity 两块校验盘.采用两种不同的校验方式来做 奇偶校验,RAID-DP 的性能优于RAID5 RAID GROUP SizeNETAPP对raid组磁盘个数的限制: RAID-DP             minimum Group size        max     de

IBM V3500存储更换控制器一例

今天一早接到客户电话,说单位内部分用户不能访问网络,我登录检查之后发现存储的一个控制器损坏导致,主要原因概述如下. 当前客户核心业务运行在vSphere虚拟化平台,该单位有3台HP服务器+1台IBM 3524存储,服务器与存储之间采用SAS接口连接,其中2台HP服务器使用SAS线连接到A控制器,另1台HP服务器使用SAS线连接到B控制器,服务器与存储之间无冗余连接.3台HP服务器安装ESXi 6.0配置成HA,所有虚拟机都保存在IBM 3524存储中,当A控制器损坏之后,前2台HP服务器丢失到存

IBM V3500存储更换控制器实例

今天一早接到客户电话,说单位内部分用户不能访问网络,我登录检查之后发现存储的一个控制器损坏导致,主要原因概述如下. 当前客户核心业务运行在vSphere虚拟化平台,该单位有3台HP服务器+1台IBM 3524存储,服务器与存储之间采用SAS接口连接,其中2台HP服务器使用SAS线连接到A控制器,另1台HP服务器使用SAS线连接到B控制器,服务器与存储之间无冗余连接.3台HP服务器安装ESXi 6.0配置成HA,所有虚拟机都保存在IBM 3524存储中,当A控制器损坏之后,前2台HP服务器丢失到存

windows系统扩展C盘的工具推荐(解决了C盘和压缩卷不相邻无法扩展C盘问题)

1.下载分区工具 “分区助手3.0中文版” 下载地址:http://www.33lc.com/soft/14880.html 2.下载下来是一个压缩包,解压后运行安装程序. 3.安装完成后按以下步骤执行完成便可实现c盘的扩展: (1)运行分区助手,点击 ‘扩展分区向导’,如下图: (2) 进入扩展向导,如下图: (3)继续下一步,如下图: (4)选择,从哪个盘分配空间给系统盘,我选择的是D盘,然后点击下一步,如下图: (5)进入分配空间界面,分配尺寸大小确定后,点击下一步,如下图: (6)进入信

IBM_DS5020磁盘阵列做raid、热备并把盘阵挂在服务器上的步骤

工作中服务器磁盘阵列里的硬盘损坏,更换新硬盘,但是还有部分扇区无法读取在此情况下重新给盘阵做raid5和热备并且把盘阵挂在服务器上. 一:准备工作 1:自己笔记本上安装IBM DS Storage Manager 10客户端软件,可从网上下载(有分32位,64位):对象是:IBM_DS5020型号的磁盘阵列. 2:通过网线直接链接笔记本和盘阵后端的A控制器,盘阵后端有A,B两个控制器,对应的默认IP如下: A控制器对应IP:192.168.128.101 B控制器对应IP:192.168.128

选盘秘籍:用户如何选择SSD/SATA/SAS?

先学习下一些专业词汇 IDE (Integrated Drive Electronics) 电子集成驱动器 它的本意是指把"硬盘控制器"与"盘体"集成在一起的硬盘驱动器.把盘体与控制器集成在一起的做法减少了硬盘接口的电缆数目与长度,数据传输的可靠性得到了增强,硬盘制造起来变得更容易,因为硬盘生产厂商不需要再担心自己的硬盘是否与其它厂商生产的控制器兼容.对用户而言,硬盘安装起来也更为方便.IDE这一接口技术从诞生至今就一直在不断发展,性能也不断的提高,其拥有的价格低廉

U盘安装Fedora-18-x86_64-DVD.iso的过程

在XP环境下,我从fedora官网上下载了Fedora-18-x86_64-DVD.iso,到本地后改名为Fedora.iso.修改U盘名称为Fedora(也可以在格式化的选项中修改) 用ultraiso_v9.5.3.2901将Fedora.iso写进U盘.1.安装过程全程区分大小写.2.过低的ultraiso不能正确读取文件.3.本文所有资料均能在网上免费下载.4.打开ultraiso以后1)文件>打开,选择Fedora.iso.并将打开后的光盘名称也改为Fedora.iso.我一般选择英文

Windows Server 2016-重命名域控制器

当公司发展到一定规模或者信息化建设到一定程度的情况下,很多信息化规范出台:很多初期服务器搭建包括服务搭建等计算机名等都是按照默认或者随机命名的,不便于区分业务或服务等.通过前边的章节我们对Active Directory域控制已经有了一定的了解,今天我们来简单介绍一下如何重命名生产环境域控制器,如下内容供大家学习参考. 重命名域控制器注意事项: a.执行重命名操作权限账户必须是Domain Admins组和Enterprise Admins组成员: b.域控制器需要是Win 2003及以上版本,