Cisco MDS9222i光纤交换机最常用排错命令

1.检查交换机端口

Show interface [interface-range]

查看指定端口运行状态,WWN信息,配置参数,收发包统计信息。

示范:

MDS9222i-1# show interface fc1/1
fc1/1 is trunking -端口fc1/1运行状态正常,是一个TE端口
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN) -端口、SFP硬件信息
Port WWN is 20:01:00:05:73:ad:2a:00 -交换机端口WWN
Peer port WWN is 20:01:00:05:73:ad:26:00 -对端WWN
Admin port mode is auto, trunk mode is on -端口模式配置是自适应,开启trunk
snmp link state traps are enabled -启用snmp链路状态变更告警
Port mode is TE -端口运行模式是TE
Port vsan is 4 -端口vsan号
Speed is 4 Gbps -端口运行速率
Rate mode is dedicated -带宽模式是dedicated
Transmit B2B Credit is 250 -发送buffer是250
Receive B2B Credit is 250 -接受buffer是250
B2B State Change Number is 14 -b2b变更关联的SCR号是14
Receive data field Size is 2112 -最大数据帧大小2112
Beacon is turned off -Beacon功能关闭
Belongs to port-channel 1 -端口属于port-channel 1
Trunk vsans (admin allowed and active) (4) -trunk vsan是4
Trunk vsans (up) (4)
Trunk vsans (isolated) ()
Trunk vsans (initializing) ()
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec -5分钟收包统计信息
5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec -5分钟发包统计信息
7468 frames input, 517940 bytes -总体收包统计信息,没有报错。
0 discards, 0 errors
0 CRC, 0 unknown class
0 too long, 0 too short
9141 frames output, 380372 bytes -总体发包统计,存在丢包现象。
3210 discards, 0 errors
330 input OLS, 240 LRR, 36 NOS, 57 loop inits -Primitive帧统计信息
340 output OLS, 271 LRR, 156 NOS, 19 loop inits
250 receive B2B credit remaining -b2b buffer信息
250 transmit B2B credit remaining
235 low priority transmit B2B credit remaining
Interface last changed at Fri Sep 7 10:59:02 2012 -端口状态最后一次变更时间。

2. 检查交换机所有端口运行状态
show interface brief
Interface -端口名称
Vsan -端口vsan号
Admin Mode -端口配置模式
Admin Trunk mode -端口是否配置trunk
Status -端口状态
SFP Mode -sfp模块信息
Oper Speed -运行速率
Port Channel -port channel号码

示范

MDS9222i-1# show interface brief

-------------------------------------------------------------------------------
Interface Vsan Admin Admin Status SFP Oper Oper Port
Mode Trunk Mode Speed Channel
Mode (Gbps)
-------------------------------------------------------------------------------
fc1/1 4 auto on trunking swl TE 4 1
fc1/2 1 FX on notConnected swl -- --
fc1/3 1 FX on up swl F 4 --
fc1/4 4094 FX on down swl -- --
fc1/5 1 FX on notConnected swl -- --
fc1/6 1 FX on init swl -- --
fc1/7 4 auto on trunking swl TE 4 1
fc1/8 1 FX on notConnected swl -- --
fc1/9 1 FX on notConnected swl -- --
fc1/10 4094 FX on inactive swl -- --
fc1/11 1 FX on notConnected swl -- --
fc1/12 1 FX on sfpAbsent -- -- --
fc1/13 1 FX on notConnected swl -- --
fc1/14 1 FX on notConnected swl -- --
fc1/15 1 FX on notConnected swl -- --
fc1/16 1 FX on notConnected swl -- --
fc1/17 1 FX on notConnected swl -- --
fc1/18 1 FX on notConnected swl -- --

-------------------------------------------------------------------------------
Interface Status Speed
(Gbps)
-------------------------------------------------------------------------------
sup-fc0 up 1

-------------------------------------------------------------------------------
Interface Status IP Address Speed MTU

-------------------------------------------------------------------------------
vsan1 up -- 1 Gbps 1500
vsan2 up -- 1 Gbps 1500
vsan3 up -- 1 Gbps 1500

3.fcping

fcping类似于以太网的ping命令,可以使用fcping fcid检测交换机到指定端口的链路通信状态,并且可以得到链路延时信息。

示范:

MDS9222i-1# fcping fcid 0x7500ef vsan 1 count 4 -fcping执行4次,对象是0x7500ef,vsan 1
28 bytes from 0x7500ef time = 1283 usec
28 bytes from 0x7500ef time = 1256 usec
28 bytes from 0x7500ef time = 1256 usec
28 bytes from 0x7500ef time = 1243 usec

4 frames sent, 4 frames received, 0 timeouts

Round-trip min/avg/max = 1243/1259/1283 usec -最小延时1243u秒,平均延时1259u秒,最大延时1283u秒。

4.检查交换机状态

show environment [clock|power|fan|temperature]命令查看交换机clock、电源、风扇、温度传感器这些模块的运行状态。show environment后面可以接一个参数,用于查看指定模块的状态。

示范:

MDS9222i-1# show environment
Clock: -始终模块。每个交换机有两个,一个active,一个standby。两个状态都是正常。
----------------------------------------------------------
Clock Model Hw Status
----------------------------------------------------------
A 0.0 Ok/Active
B 0.0 Ok/Standby

Fan: -风扇模块正常。一个三个风扇,一个交换机自带,另外两个有电源模块提供,一个电源模块自带一个风扇。
------------------------------------------------------
Fan Model Hw Status
------------------------------------------------------
ChassisFan1 DS-2SLOT-FAN 4.0 Ok
Fan_in_PS1 -- -- Ok
Fan_in_PS2 -- -- Ok
Fan Air Filter : NotSupported

Temperature: -进风口和出风口温度。
--------------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
--------------------------------------------------------------------
1 Outlet1 75 60 38 Ok
1 Outlet2 75 65 45 Ok
1 Intake1 65 50 27 Ok

Power Supply: -电源正常。电压42V,一共两个电源模块,每个提供800w功率,每个现使用掉19.05w。
Voltage: 42 Volts
-----------------------------------------------------
PS Model Power Power Status
(Watts) (Amp)
-----------------------------------------------------
1 DS-CAC-845W 800.10 19.05 Ok
2 DS-CAC-845W 800.10 19.05 Ok

5.查看交换机整体信息,包括微码版本和配置信息,各个模块的硬件参数和序列号,以及运行状态。

示范:

MDS9222i-1# show hardware |less
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Documents: http://www.cisco.com/en/US/products/ps9372/tsd_products_support_series_home.html
Copyright (c) 2002-2010, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained herein are owned by
other third parties and are used and distributed under license.
Some parts of this software are covered under the GNU Public
License. A copy of the license is available at
http://www.gnu.org/licenses/gpl.html.

Software -微码信息
BIOS: version 1.0.19 -BIOS版本
loader: version N/A
kickstart: version 5.0(4b) -kickstart版本
system: version 5.0(4b) -微码版本,正常和kickstart版本相同
BIOS compile time: 02/01/10
kickstart image file is: bootflash:/m9200-s2ek9-kickstart-mz.5.0.4b.bin -kickstart文件路径
kickstart compile time: 11/16/2010 23:00:00 [01/13/2011 15:06:13]
system image file is: bootflash:/m9200-s2ek9-mz.5.0.4b.bin -微码文件路径。这两个image文件机器启动必须用到。
system compile time: 11/16/2010 23:00:00 [01/13/2011 16:19:01]

Hardware -交换机型号
cisco MDS 9222i ("4x1GE IPS, 18x1/2/4Gbps FC/Sup2")
Motorola, e500v2 with 1036300 kB of memory.
Processor Board ID JAF1446AQAJ

Device name: MDS9222i-1 -交换机名字
bootflash: 1023120 kB
Kernel uptime is 13 day(s), 19 hour(s), 45 minute(s), 45 second(s) -交换机启动时间

Last reset
Reason: Unknown
System version:
Service:
--------------------------------
Switch hardware ID information
--------------------------------
Switch is booted up
Switch type is : MDS 9222i
Model number is DS-C9222I-K9
H/W version is 1.1
Part Number is 73-11019-01 -交换机part number
Part Revision is B0
Manufacture Date is Year 14 Week 38
Serial number is FOX1438GH5A -交换机序列号
CLEI code is COM9310ARA
--------------------------------
Chassis has 2 Module slots
--------------------------------

Module1 ok
Module type is : 4x1GE IPS, 18x1/2/4Gbps FC/Sup2
0 submodules are present
Model number is DS-X9222I-K9
H/W version is 1.5
Part Number is 73-11018-09
Part Revision is A0
Manufacture Date is Year 14 Week 46
Serial number is JAF1446AQAJ
CLEI code is COUIAMCCAE

Module2 empty

---------------------------------------
Chassis has 2 PowerSupply Slots -电源模块信息
---------------------------------------
PS1 ok
Power supply type is: 800.10W 110v AC
Model number is DS-CAC-845W
H/W version is 1.2
Part Number is 341-0052-03
Part Revision is B0
Manufacture Date is Year 14 Week 47
Serial number is QCS144710PL
CLEI code is CNUPAA8AAA

PS2 ok
Power supply type is: 800.10W 110v AC
Model number is DS-CAC-845W
H/W version is 1.2
Part Number is 341-0052-03
Part Revision is B0
Manufacture Date is Year 14 Week 47
Serial number is QCS144710RJ
CLEI code is CNUPAA8AAA
----------------------------------
Chassis has 1 Fan slots
----------------------------------
Fan1 ok
Model number is DS-2SLOT-FAN
H/W version is 4.0
Part Number is 800-24478-02
Part Revision is B0
Manufacture Date is Year 14 Week 31
Serial number is DCH143100S5
CLEI code is CNUQABBAAC

-----------------------------------------
Chassis has 1 Interface slot
-----------------------------------------
Interface module ok
Model number is DS-X9222-MGT
H/W version is 1.0
Part Number is 73-11488-02
Part Revision is A0
Manufacture Date is Year 14 Week 44
Serial number is JAF1444BJMQ
CLEI code is 0

6.检查交换机日志

show logging [logfile|nvram] 查看交换机日志信息,可以查看日志文件内容,或者nvram里面的日志信息。

7.检查zone

show zoneset [active|vsan]

查看zoneset信息,可以是当前生效zone或者是制定vsan的zone信息。

8.检查flogi

show flogi database

查看所有设备flogi信息。

MDS9222i-1# show flogi database
--------------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME
--------------------------------------------------------------------------------
fc1/3 1 0x7500ef 50:06:01:64:3c:e0:32:e7 50:06:01:60:bc:e0:32:e7
sup-fc0 1 0x750000 10:00:00:05:73:ad:2a:01 20:00:00:05:73:ad:2a:00
sup-fc0 2 0x0a0000 10:00:00:05:73:ad:2a:01 20:00:00:05:73:ad:2a:00
sup-fc0 3 0x8b0000 10:00:00:05:73:ad:2a:01 20:00:00:05:73:ad:2a:00
sup-fc0 4 0xc00000 10:00:00:05:73:ad:2a:01 20:00:00:05:73:ad:2a:00

每行包含接口,VSAN,FCID,端口WWN,节点WWN信息。Fc代表光纤口,sup-fc0代表带内管理接口,每个VSAN一个。

9.检查name server

show fcns database [vsan number]

查看所有设备的plogi信息。

MDS9222i-1# show fcns database vsan 1

VSAN 1:
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0x750000 N 10:00:00:05:73:ad:2a:01 (Cisco) ipfc
0x7500ef N 50:06:01:64:3c:e0:32:e7 (Clariion) scsi-fcp:target

VSAN 1一共包含2条name server信息。0X750000是Cisco用于交换机带内管理; 0x7500ef是一个Clariion存储的前端端口。

10.重置端口

shutdown -禁用端口
no shutdown -启用端口

时间: 2024-10-13 19:58:39

Cisco MDS9222i光纤交换机最常用排错命令的相关文章

华为交换机基本故障排错命令

华为交换机出现问题,一般都会手要你管display命令来排查故障,display命令是网络维护和故障处理的重要工具基本信息查询display diagnostic-information 或者简写 dis dia,此命令主要用于系统基本信息的收集查看设备信息 display device 简写 dis dev查看版本信息display version 简写 dis ver查看告警信息 display trapbuffer 简写 dis trap 原文地址:http://blog.51cto.co

Cisco MD9148存储交换机常用命令

9148光纤交换机常用配置 交换机基本配置 1. 配置交换机名称 switch# config terminelswitch (config)# switchname switchA 2. 配置交换机的管理IP地址 switch(config)#switch(config)# interface mgmt 0switch(config-if)# ip adress 192.168.100.10 255.255.255.0switch(config-if)# no shutdown interfa

HP ProCurve交换机与Cisco交换机生成树协议相关命令比较

相信使用HP Procurve系列交换机的朋友非常痛苦的一件事就是资料比较少,实施的案例也比较少. 这里比较了一下Cisco和HP交换机关于生成树协议(Spaninng Tree)的比较表格. 建议在边缘端口(只连接客户端电脑或非管理型交换机)上启用bpdu-protection.admin-edge-port.loop-protection这三个命令.通常由于客户端连接的设备不应该有支持生成树协议的交换机,所以对于一个稳定的网络,我们应该防止其它交换机连接到网络上来干扰已经稳定的生成树. 如果

配置Cisco MDS光纤存储交换机配置zone

配置Cisco MDS光纤存储交换机   (MDS Multilayer Director Switch 多层光纤阵列交换机) 大概流程: 1:创建VSAN,将端口加入VSAN 2:创建ZONE,将端口加入ZONE 3:创建zoneSet,将ZONE加入set,并启用zoneSet 4:启用所有端口 使用命令行基本配置MDS-1(config)#switchname MDS-1MDS-1(config)#ip default-gateway 66.66.3.254MDS-1(config)#in

交换机的工作模式命令

实验1:交换机的工作模式命令 实验目标 使用Cisco Packet Tracer构建交换机和主机的网络拓扑,三台主机和一台交换机相连,使主机之间能相互ping通并掌握交换机的常用命令的配置 实验环境 实验步骤 1. 让三台主机分别使用直连线连接交换机 2. 为主机配置IP地址,使主机之间能ping通,三台主机的IP分别为 PC0:192.168.1.1 PC1:192.168.1.2 PC2:192.168.1.3 单击主机-配置-接口配置 3. ping通主机 结果验证 4. 交换机的命令配

常用网络命令及其使用

常用网络命令使用与网络连通测试 1.Ipconfig <1>ipconfig  /all 当使用all选项时,IPConfig能为DNS和WINS服务器显示它已配置且所要使用的附加信息(如IP地址等),并且显示内置于本地网卡中的物理地址(MAC).如果IP地址是从DHCP服务器租用的,IPConfig将显示DHCP服务器的IP地址和租用地址预计失效的日期. <2>ipconfig  /release和ipconfig  /renew 这是两个附加选项,只能在向DHCP服务器租用其I

用VMware ThinApp解决Brocade光纤交换机无法WEB访问

起因: 单位买了两台存储.两台brocade光纤交换机.若干台服务器,上Oracle RAC. 但是brocade光纤交换机对JAVA版本有要求,我试了JAVA 7.X.JAVA 8.X.JAVA 6.0X.JAVA 6.3X,都无法用WEB打开.(虽然可以用命令行来配置,但是我不想为了划一个ZONE再去学命令了.) 最后用JAVA 6.24可以打开(windows xp和windows 7都可以).但是我的笔记本装的是Windows 10,装了JAVA 6.24也打不开. 过程中参考了以下这篇

77个常用Linux命令和工具

77个常用Linux命令和工具 Linux管理员不能单靠GUI图形界面吃饭.这就是我们编辑这篇最实用Linux命令手册的原因.这个指南是特别为Linux管理员和系统管理员 设计的,汇集了最有用的一些工具做为他们日常维护的参考手册.通过学习这些简单的工具,那些原本害怕命令行的人也可以变成一个脚本高手,从而通过执行 kernal命令和shell命令来最大限度的发挥linux的作用.请善用我们的指南,有任何Linux方面的问 题或者需要寻找相关答案请务必到我们 的TechTarget中国服务器论坛来发

IBM B16光纤交换机ZOON划分方法

? 一.ZOON的含义及划分原则 ????Zoon在光纤存储交换机中的功能类似于以太网交换机VLAN的作用,主要是为了在一台交换机划分出多个逻辑区,用于防范不同应用的存储连接发起广播包,提高光纤交换机的利用率. ????ZOON划分原则上至少要有两个节点,可以基于交换机端口或光纤适配器的WWN号(即别名方式). ? 二.基于RJ45网络的WEB方式 (一)配置网络接入交换机 ????配置好IP地址同为10.77.77.77.0网段的任何地址,确保控制台装有JAVA环境,如果没有可以上SUN网站上