一、划zone(以博科光纤交换机为例)
①查看光纤交换机端口状态
RAC_SW_01:admin> switchshow Index Port Address Media Speed State Proto ================================================== 0 0 010000 id N8 Online FC F-Port 50:06:01:61:09:60:31:xx 1 1 010100 id N8 Online FC F-Port 10:00:00:00:c9:83:76:xx 2 2 010200 id N8 Online FC F-Port 10:00:00:00:c9:83:76:xx 3 3 010300 id N8 No_Light FC 4 4 010400 id N8 Online FC F-Port 50:06:01:69:09:60:31:xx 5 5 010500 id N8 No_Light FC 6 6 010600 id N8 No_Light FC 7 7 010700 id N8 No_Light FC 8 8 010800 id N8 No_Light FC
②对光纤交换机0、1、2、4号端口创建别名
alicreate "vnx5200_spa1","1,0"
alicreate "node02_1","1,2"
alicreate "node01_1","1,1"
alicreate "vnx5200_spa1","1,4"
alishow可以查看对应端口的别名
③创建zone并绑定对应端口
zonecreate "vnx5200_spa1_node01_1","vnx5200_spa1; node01_1"
zonecreate "vnx5200_spb1_node01_1","vnx5200_spb1; node01_1"
zonecreate "vnx5200_spa1_node02_1","vnx5200_spa1; node02_1"
zonecreate "vnx5200_spb1_node02_1","vnx5200_spb1; node02_1"
④创建配置文件
cfgcreate "sw01_cfg","vnx5200_spa1_node01_1;vnx5200_spb1_node01_1;vnx5200_spa1_node02_1;vnx5200_spb1_node02_1"
⑤保存配置文件
cfgsave
⑥使配置文件生效(每台交换机当前只能一个配置文件生效)
cfgenable "sw01_cfg"
到这一步光纤交换机配置全部完成,另外一台执行相同操作即可。
二、在SAN存储划分好LUN,设置好对应的HostGroup做好映射关系,不同的厂商有不同的做法,大同小异
三、主机上的相关操作
①查看映射的LUN信息
以RHEL6.5为例,默认做好上面两步之后,可以使用fdisk -l或者cat /proc/partitions可以看到未做聚合前的物理盘(scisi盘一般以/dev/sd*显示),一个LUN有多条路径。
安装配置多路径软件后才能看到聚合盘(聚合后的盘在/dev/mapper/$name目录下),不同厂商的多路径软件显示的聚合盘名称不一样。
扩展:如果直接对未做多路径的物理盘做分区使用,会导致多条路径不能负载均衡且只有一块盘可以读写,所以都是对安装多路径软件后的聚合盘做分区来使用的。
RHEL6.5 multipath多路径显示如下:
EMC powerpath多路径显示如下:
②安装multipath多路径软件及相关配置文件设置
yum install device-mapper*
针对重启之后磁盘标识符改变的解决办法(udev磁盘设备绑定)
针对大于2TB的GPT分区